Automatic Shield Line Classification

Summary

This function needs to divide the shield lines into conductors in advance; after this function, the shield lines will be automatically separated. The function interface is shown in the figure below. This function can process multiple data at the same time.Clickto add data. Clickto remove selected data. Clickto remove data list.

Usage

Click Toolbox > Point cloud Processing > Automatic Shield Line Classification

AutoClassifyShieldLine

Parameters

  • Layer Number: The number of layers of lines before classification.
  • Slice thickness: The slice thickness of the wire cut along the transverse direction.
  • Cluster Threshold(m)(3.5 by default): When the point cloud data is clustered, the maximum spatial separation distance, the power line points smaller than the threshold will be clustered into a cluster.
  • Middle Phase width(m)(2 by default): The width of the mid-phase area.
  • Num of thread(4 by default): Set the number of running threads of the function, which can support 1-32 threads. The software can record the user's current setting and automatically restore the setting when it is opened again.

results matching ""

    No results matching ""