Insulator Analysis
Summary
This function is used to calculate the inclination information of insulators in power lines and generate analysis reports. This function requires classification of insulators in advance. The function interface is shown in the figure below. This function can process multiple data at the same time. Click to add pending data, clickto remove the selected data, click to clear data list.
Usage
Click Completion Analysis > Insulator
Settings
- Insulator Class(default value is "27"): Class number of insulators in point cloud data.
- Cluster Threshold(meters)(default value is "3.5"): The maximum spatial spacing distance for the clustering of insulator point cloud data, and insulators less than the threshold will be clustered into a cluster.
- Generate Report: This option is checked by default. If this option is checked the analysis report will be generated; if the option is unchecked, the analysis report will not be generated.
- Assessor Company: The company which generates the report.
- Electrical Transmission Bureau/Company: The name of power supply bureau or company.
- Line Name: Line name.
- Target Coordinate: The coordinate system used in the report.
- Report Path: The output path of the report.
- Threads Num(default value is "4"): Set the number of thread (1 to 32) to run this function. The software can record the currently setting and when the user open this function again, the setting will be kept.