Phase Spacing Analysis

Summary

This function is used to calculate and analyze the distances between power lines, and then generate the analysis report. The phase spacing will change if the distance is too long or too short; the temperature is too high; or the line is broken. Click to add the data to be processed. Click to remove the selected data. Click to clear the data list.

Usage

Click Completion Analysis > Phase Spacing

Phase Spacing Analysis

Settings

  • Phase Spacing Analysis: This option is checked by default. If it is checked, the software will perform phase spacing analysis; if not, the function will not be executed.
    • Profile Thickness (meters) (default value is "5.0"): The thickness of the cross profile of the power line which is used to extract the point cloud for calculating. The software can record the currently setting and when the user open this function again, the setting will be kept.
    • Cluster Threshold (meters) (default value is "3.5"): The maximum spatial separation distance when the point cloud data is clustered. Power line points smaller than the threshold will be clustered into a cluster. The software can record the currently setting and when the user open this function again, the setting will be kept.
    • Calculate Horizontal Distance of Double Circuit Line: Not selected by default. When selected, if the power line is a double loop, the horizontal distance between the left and right sides will be calculated.
    • Based On Shp File: Not selected by default. When selected, a power line vector file can be added, and the vector is used as the basis for calculating the distance between phases. Suitable for special sections of certain line situations.
  • Generate Report: This option is checked by default. If this option is checked the analysis report will be generated; if the option is unchecked, the analysis report will not be generated.
    • Assessor Company: The company which generates the report.
    • Electrical Transmission Bureau/Company: The name of power supply bureau or company.
    • Line Name: Line name.
    • Target Coordinate: The coordinate system used in the report.
    • Report Path: The output path of the report.
  • Threads Num(default value is "4"): Set the number of thread (1 to 32) to run this function. The software can record the currently setting and when the user open this function again, the setting will be kept.

Note: After the detection, the software will export the detection result file for each segment. User can check the accuracy of the analysis in phase spacing analysis list. Each row contains a phase spacing. And the name, coordinates of the target point, and the point cloud it belongs to will be recorded in different columns.